{"id":3739,"date":"2026-11-10T04:54:50","date_gmt":"2026-11-09T20:54:50","guid":{"rendered":"http:\/\/www.good-kicks.com\/blog\/?p=3739"},"modified":"2026-11-10T04:54:50","modified_gmt":"2026-11-09T20:54:50","slug":"how-to-identify-the-conductor-size-of-a-control-cable-43a0-a431f4","status":"publish","type":"post","link":"http:\/\/www.good-kicks.com\/blog\/2026\/11\/10\/how-to-identify-the-conductor-size-of-a-control-cable-43a0-a431f4\/","title":{"rendered":"How to identify the conductor size of a control cable?"},"content":{"rendered":"<p>If you\u2019ve ever stood in front of a bin full of control cable reels, running your fingers over the insulated jackets and squinting at tiny printed markings, you know how overwhelming it can be to pull the right conductor size for a job. I\u2019ve been selling control cable for 12 years\u2014first as a tech in our warehouse, then as a rep talking to plant managers, electricians, and automation engineers across the Midwest\u2014and the question I get most often isn\u2019t \u201cwhat control cable do I need\u201d but \u201chow do I actually figure out if this conductor is the right size?\u201d A lot of folks guess by the insulation color or the thickness of the jacket, or go by a vague number on a old spec sheet that\u2019s been yellowed in a binder for 10 years. But guessing leads to headaches: overheating circuits, extra downtime, even safety risks. Today I\u2019m breaking down exactly how to identify a control cable\u2019s conductor size, straight from the supplier that\u2019s shipped 100,000 reels to jobs just like yours. <a href=\"https:\/\/www.huawang-cable.com\/control-cable\/\">Control Cable<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.huawang-cable.com\/uploads\/45208\/page\/small\/flexible-instrument-cablecb945.jpg\"><\/p>\n<p>First, let\u2019s start with the basics: control cable conductors aren\u2019t like extension cord wires, and their sizing isn\u2019t just about how thick the plastic feels. Control cables are used for low-voltage circuits\u2014think PLC controls, motor starters, sensor signals, and interlock wiring in factories, office buildings, and even farm operations. They carry small amounts of power, usually between 12V and 600V, but that means their conductors have to carry consistent current without dropping voltage or overheating. The size of that conductor directly impacts current-carrying capacity, voltage drop, and even how flexible the cable is (super important if you\u2019re running it through tight conduit or moving machinery).<\/p>\n<p>Let\u2019s go step by step, starting with the fastest, most reliable check: the printed markings right on the cable jacket. Every reputable control cable manufacturer prints critical specs on the outer sheath, usually along the length every 12 inches or so. If you can find that printed text, you\u2019re 90% of the way there. Look for lines that say \u201cAWG\u201d or \u201cAmerican Wire Gauge\u201d\u2014that\u2019s the standard for control cable in North America, and it\u2019s the sizing system most of our customers know. You\u2019ll see numbers like 14 AWG, 16 AWG, 18 AWG, even 22 AWG for small signal cables. If you see \u201cmm\u00b2\u201d (square millimeters) instead, that\u2019s the metric sizing used in many global applications, and you can easily convert that to AWG if you work in North America (1 mm\u00b2 is roughly 18 AWG, 1.5 mm\u00b2 is 16 AWG, 2.5 mm\u00b2 is 14 AWG\u2014memorize that, it\u2019ll save you a call).<\/p>\n<p>Wait, you might say, I found a number, but is that the individual conductor or the whole cable? Great question\u2014we get that all the time. If it says, for example, \u201c18\/14 AWG,\u201d that\u2019s easy: that means 14 individual 18 AWG conductors. If it says \u201c14 AWG total,\u201d that\u2019s more likely a multi-conductor cable where each individual conductor is 14 AWG\u2014though sometimes manufacturers will list the total cross-sectional area, so double-check the wording. Another marking to look for: \u201cStranding\u201d specs. You\u2019ll see something like \u201c7\/30\u201d or \u201c19\/32\u201d printed too. That\u2019s how many thin wires make up each individual conductor. The first number is the total strands, the second is the gauge of each strand. For control cable, higher strand counts (like 19 or 37 strands, not just 7) mean more flexibility, which is why you see those numbers on cables meant for moving equipment, like crane controls or robotic arms. That stranding number doesn\u2019t change the AWG size, though\u2014so even a 19\/30 16 AWG conductor is still 16 AWG for sizing purposes.<\/p>\n<p>Now, what if the cable has no markings? Maybe it\u2019s an old reel you\u2019ve had in your warehouse for 10 years, or a leftover from a job you can\u2019t trace the spec sheet for, or it\u2019s a used cable you pulled from an old machine. That\u2019s where we run physical checks. First, you need to strip a small section of the insulation from one end of an individual conductor\u2014be gentle, don\u2019t nick the copper (or aluminum, though aluminum is rare in control cable) wire inside, that would throw off your measurement. Once the insulation is off, you have the bare conductor left.<\/p>\n<p>The most accurate physical check is a micrometer\u2014if you have one, even a basic digital micrometer costs less than $20 and is worth every penny. Measure the diameter of the bare conductor at three different points to account for any slight imperfections, then average those numbers. If you know your AWG table, you can match that diameter: 18 AWG is about 1.02 mm in diameter, 16 AWG is 1.29 mm, 14 AWG is 1.63 mm. If you don\u2019t have a memorized table, pull up a reliable one on your phone (I keep a saved one in my work contacts, honestly) and cross-reference. If you only have a tape measure or a ruler, wrap the conductor tightly around a pencil 10 times, measure the total width of that wrapped section, divide by 10 to get the diameter, then match that to the AWG size. It\u2019s less accurate than a micrometer, but it works for field checks.<\/p>\n<p>Wait, what if the conductor is stranded? Don\u2019t panic\u2014same process. For stranded conductors, measure the total cross-sectional area (you can do this with the diameter of the whole stranded bundle, minus the insulation, same as a solid conductor) and that will match the AWG size. Remember, higher strand counts mean the same AWG, just more flexible, so a stranded 16 AWG is not a different size than solid 16 AWG. The only time you have to worry is if you\u2019re mixing solid and stranded for the same job\u2014they fit differently in terminals, but that\u2019s a installation issue, not a sizing one.<\/p>\n<p>Now, let\u2019s talk about common mistakes we see customers make, because even when you do all these checks, it\u2019s easy to mix up sizes. First, confusing control cable with power cable. Power cable is usually thicker, higher current, and might have different AWG sizing that looks similar but is not the same. For example, a 12 AWG power cable is for heavy circuits, but you\u2019ll never see a 12 AWG control cable\u2014most control cables top out at 10 AWG for motor leads, and go down to 26 AWG for sensors. Second, ignoring the conductor material. Most control cable conductors are bare or tin-plated copper, which is standard, but aluminum conductors (used only for very large, low-voltage runs) have a slightly different current rating, so make sure your spec sheet matches the material. Third, misreading markings on old cables. Printing fades, so if the text looks blurry, run your finger over it with a small amount of rubbing alcohol\u2014sometimes the ink comes back enough to read the AWG number, no need to strip the whole reel.<\/p>\n<p>Another trick we share with all our new customers: when in doubt, pull up our product library. I work with a team that\u2019s updated our online spec database every year for 12 years, and every control cable we sell has a full breakdown of conductor size, stranding, jacket material, and current rating. If you send us a photo of the printed markings, or the diameter of a stripped conductor, we can tell you exactly the size in 2 minutes flat. We do this all the time\u2014last month, a electrician from Chicago sent us a photo of an old reel he found in the back of a warehouse, and we confirmed it was 18 AWG stranded control cable, which he needed to rewire a conveyor belt. Saved him an hour of guessing and a trip to the supply house.<\/p>\n<p>Now, why does this matter beyond just getting the right part? We\u2019ve seen the cost of getting conductor size wrong. A customer in Ohio ordered 14 AWG control cable for a sensor circuit, thinking that\u2019s what their old job used, but it was actually 16 AWG. The smaller conductor meant higher voltage drop, so the sensor couldn\u2019t send a signal correctly, shutting down their whole assembly line for 8 hours. The fix? Replace it with the right 16 AWG cable, costing them $200 in parts, but the downtime cost them $12,000 in lost production. That\u2019s why taking 5 minutes to confirm conductor size saves you way more time and money in the long run.<\/p>\n<p>Let\u2019s wrap this up with a quick checklist you can keep in your toolbox next time you\u2019re verifying control cable conductor size:<\/p>\n<ol>\n<li>Check the printed jacket markings for AWG or mm\u00b2.<\/li>\n<li>Confirm the number before AWG is the individual conductor size (not total cable size).<\/li>\n<li>If markings are faded or missing, strip a small section of an individual conductor.<\/li>\n<li>Measure the diameter (use a micrometer for accuracy, or the pencil wrap method for field checks).<\/li>\n<li>Cross-reference with a reliable AWG sizing chart, or reach out to your control cable supplier for help.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/www.huawang-cable.com\/uploads\/45208\/small\/single-core-flexible-wirefc07b.jpg\"><\/p>\n<p>At the end of the day, identifying conductor size isn\u2019t rocket science, but it does require a little attention to detail. We\u2019ve built our business on being the kind of control cable supplier that doesn\u2019t just sell you a reel and disappear\u2014we\u2019re here to help you get the right part, every time, even if you\u2019re not sure what you\u2019re looking at. If you\u2019re working on a project and need to confirm a control cable\u2019s conductor size, or if you\u2019re looking to spec control cable for a new job, we\u2019re ready to walk through the details with you. Just reach out to our team to discuss your requirements.<\/p>\n<p><a href=\"https:\/\/www.huawang-cable.com\/vfd-cable\/\">VFD Cable<\/a> References:<\/p>\n<ol>\n<li>National Electrical Manufacturers Association (NEMA) Standard WC 5, for Control Cables, Conductor Size and Construction, 2021<\/li>\n<li>International Electrotechnical Commission (IEC) Standard 60227, for Insulated Cables for Rated Voltages Up to and Including 450\/750 V, 2020<\/li>\n<li>American Wire Gauge (AWG) Standard, National Institute of Standards and Technology (NIST) Handbook 181, 2019<\/li>\n<li>Control Cable Application Guide, Underwriters Laboratories (UL) Standard 62, for Control Circuit Cables, 2022<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.huawang-cable.com\/\">Anhui Huawang Cable Co., Ltd.<\/a><br \/>As one of the most professional control cable manufacturers and suppliers in China, we also support customized service. If you&#8217;re going to buy discount control cable, welcome to get pricelist from our factory. Quality products and reasonable price are available.<br \/>Address: No. 32, East Street, Batian Street, Datong Town, Tianchang City, Anhui Province<br \/>E-mail: Linda@huawangcable.com<br \/>WebSite: <a href=\"https:\/\/www.huawang-cable.com\/\">https:\/\/www.huawang-cable.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever stood in front of a bin full of control cable reels, running your &hellip; <a title=\"How to identify the conductor size of a control cable?\" class=\"hm-read-more\" href=\"http:\/\/www.good-kicks.com\/blog\/2026\/11\/10\/how-to-identify-the-conductor-size-of-a-control-cable-43a0-a431f4\/\"><span class=\"screen-reader-text\">How to identify the conductor size of a control cable?<\/span>Read more<\/a><\/p>\n","protected":false},"author":156,"featured_media":3739,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3702],"class_list":["post-3739","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-control-cable-4d05-a4747e"],"_links":{"self":[{"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/posts\/3739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/users\/156"}],"replies":[{"embeddable":true,"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/comments?post=3739"}],"version-history":[{"count":0,"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/posts\/3739\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/posts\/3739"}],"wp:attachment":[{"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/media?parent=3739"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/categories?post=3739"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.good-kicks.com\/blog\/wp-json\/wp\/v2\/tags?post=3739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}